Age of serum proteins was performed on a semiauto mated hydrasys system sebia using the hydragel pro teine 1530 reagent set. L of sample was applied manually to the sample template. Sebia continuously reinvests in research and development of new products to help automate workflow and increase productivity in the clinical laboratory. Enhanced gel electrophoresis versus capillary electrophoresis. Withinrun and betweenrun imprecision for the five electrophoretic fractions was spe and immunofixation electrophoresis ife tests the following cpt codes are used to report spe and ife testing. Jul 08, 20 an m protein may be easily overlooked or an apparent m protein may actually represent a polyclonal increase in immunoglobulins or another protein if an m protein is present, the immunoglobulin heavy and light chain class cannot be determined from the spep consequently, the lab must perform serum ife in order to ascertain the presence of an m. Materials and methods agarose gel electrophoresis protein electrophoresis was performed using the semiautomated sebia hydrasys system with the hydragel protein 1530 reagent set sebia according to the manufacturers instructions. For example, a fundamental term in chromatography is retention time. The sebia capillary electrophoresis ce instruments, capillarys and minicap, have been developed to provide complete automation, with fast separation and high resolution. Electrophoresis terminology there are a few significant differences between the nomenclature of chromatography and capillary electrophoresis. Withinrun and betweenrun imprecision for the five electrophoretic fractions was protein structure and electrophoresis 1 2 techniques for protein electrophoresis 15 3 immuno. Protein immunofixation is a wellestablished technique used to type any suspected monoclonal component previously detected by serum protein electrophoresis.
It is used in conjunction with the capillarys proteine 6 kit, sebia. The title has been changed from highresolution electrophoresis and immuno. Performance of the sebia capillarys 2 for detection and. In this report, we evaluate automated capillary zone electrophoresis by capillarys. The capillarys system sebia, issylesmoulineaux, france was operated. Capillarys proteine 6 207 intended use the capillarys proteine 6 kit is designed for the separation of human serum and urine proteins in alkaline buffer ph 9. Hb lepore hb lepore has an abnormal beta chain made up of the beginning of the delta chain and the end of the beta chain. Protein electrophoresis is a wellestablished technique routinely used in clinical laboratories for screening of serum and other fluids for protein abnormalities.
Protein electrophoresis 84165 protein, electrophoretic fractionation and quantification, serum 84166 protein, electrophoretic fractionation and quantification, other fluids with concentration eg, urine, csf 83916 oligoclonal immune, oligoclonal bands. Sebia is pleased to offer text books specifically related to serum and urine protein electrophoresis and immunofixation testing, as well as the diagnosis of hemoglobinopathies. The hydragel protein e assay is based on the principle of electrophoresis separation on agarose gel. Serum protein electrophoresis is used to identify patients with multiple myeloma and other serum protein disorders. This arises from a cross over between the two chromosomes 11 as shown in the diagram.
Jan 01, 2005 serum protein electrophoresis is used to identify patients with multiple myeloma and other serum protein disorders. Sebia capillary capillary 7 mpaser gels 4 umpa gels abstract gel electrophoresis and capillary electrophoresis are commonly used for serum and urine protein analysis in the medical laboratory. Protein electrophoresis was performed using the sebia hydragel 7 and 1530 protein kits in conjunction with the semi. The pattern of serum protein electrophoresis results depends on the fractions of two major types of protein. This test allows the separation and the quantification of. An m protein may be easily overlooked or an apparent m protein may actually represent a polyclonal increase in immunoglobulins or another protein if an mprotein is present, the immunoglobulin heavy and light chain class cannot be determined from the spep consequently, the lab must perform serum ife in order to ascertain the presence of an m. Serum protein electrophoresis and immunofixation by a. Very often, ce refers to capillary zone electrophoresis cze, but other electrophoretic techniques including capillary gel electrophoresis cge, capillary isoelectric focusing cief, capillary isotachophoresis and micellar.
Jun 21, 2015 capillary electrophoresis is an analytical method that separates ions founded on their electrophoretic mobility with the usage of an utilized voltage. The hydrasys and hydrasys 2 are compact systems that carry out all phases of electrophoresis from sample application to migration to incubation to staining. It is a revision of two previous books on this subject with several substantive and many trivial changes. Agarose is used in some applications such as for the separation of proteins larger than about 500 kda and for immunoelectrophoresis 6, 12. Automated multicapillary electrophoresis for analysis of. Capillary zone electrophoresis cze of serum proteins is increasingly gaining impact in clinical laboratories. Sebia, inc karen anderson director of technical and.
Indications for use the hydrashift 24 daratumumab test is intended for the qualitative detection of monoclonal proteins in human serum by immunofixation electrophoresis. Serum protein electrophoresis and immunofixation by a semiautomated electrophoresis system xavier bossuyt, ann bogaerts, gilberte schiettekatte, and norbert blanckaert semiautomated agarose electrophoresis and immunofixation performed with hydrasyshyrysy sebia were compared with conventional, manually performed methods, including cellulose. Evaluation performance of protein electrophoresis and immunofixation using sebia hydrasys 2 scan, sebia capillarys 2 flex piercing and interlab g26. Pdf automated serum protein electrophoresis by capillarys. Hemoglobin electrophoresis in acid agar would show this abnormal hemoglobin migrating as hb a. Protein electrophoresis is a well established technique routinely used in clinical.
However, agarose gels are not used much in protein work and they are not discussed in this section. Albumin, the major protein component of serum, is produced by. Protein separation by capillary gel electrophoresis. Evaluation performance of protein electrophoresis and immunofixation using sebia hydrasys 2 scan, sebia capillarys 2 flex piercing and interlab.
Protein electrophoresis is a wellestablished technique routinely used in clinical laboratories for screening of protein abnormalities in serum and other biological fluids. Protein electrophoresis is a well established technique routinely used in clinical laboratories for. The kits are to be used in conjunction with the hydragel if kits and the semiautomated hydrasys 2 electrophoresis apparatus. We evaluated a new, automated multicapillary zone electrophoresis ce instrument capillarys, 4. We perform over 4,000 serum and urine specimens monthly for protein and immunofixation testing. Summary hemoglobins hb are a group of proteins whose chief functions are to transport oxygen from the lungs to the tissues and carbon dioxide in the reverse direction. Urine protein electrophoresis upe and immunofixation ulf are central in the diagnosis and follow up of patients with monoclonal gammopathies. Electrophoresis separates proteins based on their physical properties, and the. Sebia is the worlds leading provider of clinical protein electrophoresis equipment and reagents, a technology used for invitro diagnostic ivd testing.
Electrophoresis codes the following cpt codes are used to report electrophoretic procedures. Csf protein electrophoresis as well as for electrophoresis of specific proteins such as enzymes alp, ck and ldh, lipoproteins and hemo. Sebia electrophoresis products hydrasys hydrasys 2. Due to the technology advancement, current cge methods are becoming more and more robust and reliable for protein analysis, and some of the methods have been routinely used for the analysis of proteinbased pharmaceuticals and quality controls. The hydrasys system is a semiautomated multiparameter instrument. Capillary electrophoresis ce technology allows the laboratory to completely automate electrophoresis testing for protein, immunotyping, cdt, and hemoglobinopathy analysis. In electrophoresis, under ideal conditions, nothing is retained, so the analogous term becomes migration time. Serum protein electrophoresis is a routine test performed in the majority of medical analysis laboratories. Each year, we perform approximately 30 000 hba1c, 11 000 protein electrophoresis and. The automated steps include processing of the agarose gel in the following sequence. The semiautomated gel electrophoresis instrument, hydrasys, has been developed to provide a complete test panel with high sensitivity and good resolution.
Helenas hemoglobin electrophoresis procedure, using cellulose acetate in alkaline buffer, is intended for the qualitative and quantitative determination of abnormal hemoglobins. The capillarys protein e 6 kit is designed for the separation of human serum and urine proteins in alkaline buffer ph 9. Micropipettor, either manual or automated, such as hydraplus sebia, pn. Pdf evaluation performance of protein electrophoresis. The hydragel if kit allows the separation and characterization of immunoglobulins heavy and light chains using specific antisera. This text presents the use of protein electrophoresis of serum, urine, and cerebrospinal.
Jan 04, 2012 capillary gel electrophoresis cge has been used for protein separation for more than two decades. Each vial of the stock hydrasys wash solution sebia, pn 4541, 10 vials. Capillary gel electrophoresis cge has been used for protein separation for more than two decades. Capillary electrophoresis ce is a family of electrokinetic separation methods performed in submillimeter diameter capillaries and in micro and nanofluidic channels. Immunotyping procedure allows for specific identification of such immunoglobulin. Capillary zone electrophoresis cze of serum proteins is increasingly gaining. Due to the technology advancement, current cge methods are becoming more and more robust and reliable for protein analysis, and some of the methods have been routinely used for the analysis of protein based pharmaceuticals and quality controls. Proteins identified by serum protein electrophoresis. Withinrun and betweenrun imprecision for the five electrophoretic fractions was electrophoresis is a general term that describes the migration and separation of charged particles ions under the influence of an electric field. Aes application focus gel electrophoresis of proteins page 3 protein electrophoresis.
We compared the new fully automated capillary electrophoresis system from sebia, capillarys, with our reference method, agarose gel electrophoresis hydrasys sebia. Interlab is a company devoted entirely to the protein electrophoresis industry and provides quality service to its customers. S erum protein electrophoresis is a laboratory examination that commonly is used to identify patients with mul. Serum protein electrophoresis is an inexpensive, easytoperform screening procedure for initial identification of monoclonal bands. Sebias semiautomated agarose gel electrophoresis systems are designed to automate the many tedious steps involved in traditional electrophoresis and immunofixation testing. Semiautomated agarose electrophoresis and immunofixation was performed with the hydrasys automate according to the manufacturers instructions, using hydragel 15 and 30 proteine and hydragel 2 and 4 immunofixation gels sebia. Agarose gel electrophoresis and immunofixation semiautomated age and immunofixation were performed with the hydrasys automate sebia, issylesmoulineaux, france, using hydragel protein five band and hydragel imemail of the corresponding author. Understanding and interpreting serum protein electrophoresis. Text books solely focused on the discipline of electrophoresis testing can be difficult to find. In this report, we evaluate automated capillary zone electrophoresis by capillarys sebia, france. An electrophoretic system consists of two electrodes of opposite charge anode, cathode, connected by a conducting medium called an electrolyte.
Interlab, founded in 1976 and part of the sebia group since september 2016, exports its products to more than 40 countries around the world. Sebia is pleased to offer text books specifically related to serum and urine protein electrophoresis and immunofixation testing, as well as the diagnosis of hemoglobinopathies with capillary electrophoresis technology. The semiautomated gel electrophoresis instrument, hydrasys, has been developed to provide a complete test. Serum protein electrophoresis an overview sciencedirect. Normal serum proteins separate into six major fractions. Automated serum protein electrophoresis by capillarys. Since several years, serum proteins electrophoresis became a routine analysis, mainly performed by agarose gel electrophoresis, frequently semiautomated. Pdf evaluation performance of protein electrophoresis and. The separated proteins were stained with amido black and densitometric scanning was performed.
781 764 405 869 1591 980 366 1046 754 1122 329 480 569 1084 494 484 307 873 82 1389 1359 518 1197 218 449 1290 769 320 568 323 1239 1200 151 466 653 1311 605 1352 232 259 1430 1258 911